Shop by Category

banner banner

Dive Perfect Matilda Streamlined Sport Diver Regulator Package

DP-MATILDA-SPORT
Dive Perfect
Starting at: $1,199.00





Qty:         

The Dive Perfect Matilda Streamlined Sport Diver Regulator Package is a definitive blend of style, ruggedness and high performance. Every detail of this product has been carefully designed to deliver a regulator package of the highest quality with improved safety. These regs meet the tough CE EN250 European standards, and are cold water and Nitrox ready.

The Dive Perfect Matilda Streamlined Sport Diver Regulator Package includes:

The full package comes completely assembled by The Scuba Doctor with our premium accessories and is ready to dive anywhere in the world.

Streamlined Sport Diver Regulator Configuration

The Streamlined Sport Diver regulator set up is designed to keep hoses from dangling and also to maximise diver comfort. This configuration is very streamlined and efficient. It's the most popular single tank package configuration style offered by The Scuba Doctor.

In the streamlined configuration, the 120 cm longer hose on the primary regulator routes under the diver's arm, lies flat against the chest, and neatly joins the second stage with a 20/110° swivel adaptor, reducing mouth fatigue. The backup/octopus regulator is tucked safely under the diver's chin using a regulator necklace, allowing immediate access in an emergency. The 60 cm shorter hose on the backup/octopus regulator is more streamlined reducing drag. In an emergency, the primary is donated while the backup is always instantly available.

Technical divers always donate their longer hose primary, and never colour code either regulator. For sport diving with the streamlined configuration, we also prefer the covers of both primary and backup second stages to be black. However, if you agree with the sport diving theory that in an out-of-air situation the donated regulator should be clearly apparent in the golden triangle, then the primary should have a yellow cover, and maybe even a yellow hose. We can supply this configuration if required.

This package also includes your choice of a Single Console with SPG Gauge only, or a Dual Console with SPG and Depth Gauges. The console is clipped to the waist D-ring using the supplied stainless steel swivel bolt snap. Or use your existing console/gauge and save money.

The Streamlined Sport Diver package also includes a Miflex low pressure BCD/Jacket/Inflator hose for your BCD, if required. You may choose from the shorter length 56 cm (22") hose, the standard length 60 cm (24") hose, or a longer length 65 cm (24") hose. Alternatively, you can go with your existing BCD inflator hose and save money.

Features and Benefits

The first stage regulator is supplied in 300 bar DIN configuration for added safety and lightness for travel. The included DIN to Yoke Adaptor enables you to easily switch to using the 1st stage with Yoke cylinder valves, should this be required. The include DIN Regulator Cap helps you to better care for your regulator and keep it in excellent condition.

The environmentally sealed chamber 1st stage regulator is suitable for cold water use (below 10°C / 50°F).

The first and second stage regulators are compatible with EAN40 out of the box. They can be cleaned for use with 100% Oxygen.

Double braided flexible hoses are standard. These hoses are lighter weight, more flexible and more durable.

The hoses are setup in the Streamlined Sport Diver Regulator Configuration. This is a much safer setup, plus significantly reduces drag.

The second high pressure port makes it easy to add a dive computer pressure transmitter. The fourth low pressure port makes it easy to add a drysuit inflator hose.

Dive Perfect Matilda FS-808 DIN ICE First Stage:

  • FS style first stage.
  • Highly polished bright chrome plating.
  • Compact one piece body.
  • 4 angled medium pressure ports, 4 x 3/8"-24 UNF.
  • 2 angled high pressure ports, 2 x 7/16"-20 UNF.
  • Over-balanced, diaphragm design - as the diver descends, the over-balancing feature allows the medium pressure gas in the hose to increase at a rate faster than ambient. This results in superior performance at depth.
  • An environmental dry system keeps water out of the main spring chamber thus preventing ice buildup and keeping silt and contamination out
  • The 1st stage can be fitted to the cylinder any way up. It doesn't matter, it comes down to personal choice. The orientation does not affect the function of the regulator.

Dive Perfect FR-02 Second Stage

  • Pneumatically-balanced second stage results in smooth, easy breathing.
  • The FR-02 purge buttons are large and easy to operate. A 2-stage progressive purge is used - press the purge on the side for a lower flow rate, useful where more control is required such as filling lift bags etc, then press in the centre for the full effect of the purge, i.e. when regulator clearing etc.
  • The large venturi lever is easy to locate and use. The lever reduces the amount of grit ingress and therefore resists any possible friction giving a smooth operation.
  • Easy-to-grip opening effort control knob keeps the diver in control.
  • The comfortable mouthpiece virtually eliminates jaw fatigue.
  • A heat exchanger dissipates the cold caused by gas expansion while drawing in the warmth of the ambient water.

Note: This package includes two Dive Perfect FR-02 Second Stage regulators. We do not use a lower performance unit for the backup/octopus regulator. In an emergency, both divers get to use identical high quality, top performance regulators.

Specifications

Dive Perfect Matilda FS-808 DIN ICE 1st Stage Regulator

Connections 300 bar DIN for added safety
Type of first stage Over-balanced diaphragm design.
Environmentally sealed
Body Type One piece forged body
Number of HP ports 2 x 7/16"-20 UNF
Number of LP ports 4 x 3/8"-24 UNF
Environmental Dry Kit Standard
First stage exterior Chrome over marine brass
Cold Water Use Yes

Dive Perfect FR-02 2nd Stage Regulator

Type of second stage Pneumatically balanced
Opening Effort Control Knob Yes
Integrated Venturi Lever Yes
Mouthpiece Comfortable mouthpiece
Heat Exchanger for freezing resistance Yes
Hose type Double braided flexible hose
Nitrox compatible Yes to 40% O2 when new, out of the box.
Can be cleaned for 100% Oxygen.

First Stage Technology

Over-balanced Diaphragm Design

The heart of any regulator is the first stage. The Dive Perfect Matilda FS-808 DIN ICE 1st Stage Regulators utilise an over-balanced diaphragm design. In an over-balanced first stage design, the inter-stage pressure in the hose increases faster than traditional balanced models as a diver descends to greater depths. This increased inter-stage pressure compensates for the increased density of your breathing gas by allowing a larger volume of gas to flow through the system on demand. The result is superior breathing performance regardless of depth.

Environmental Dry Sealing System

Standard on the Dive Perfect Matilda FS-808 DIN ICE first stages is the Environmental Dry Sealing System. This system serves a number of purposes, including the prevention of ice build up on the main spring that can occur when diving in extremely cold water. Dry sealing the first stage also acts as a safeguard against the entry of contaminants and silt into the main spring chamber, and eliminates the need for messy silicone oil or grease filling inside your regulator.

The Environmental Dry Sealing System enables the regulator to meet the European Standard for cold water regulators (as defined by CE EN250), which means that the regulator has been certified for use in water as cold as 2 to 4 degrees Celsius (35.6 to 39.2 degrees Fahrenheit). If you dive primarily in cold/temperate waters, like in Southern Australia, you need to make sure that the regulator you're getting is suitable.

The Environmental Dry Sealing System also comes into its own if you'll be diving in waters that are silty, sandy, or high in dissolved solids. The environmentally sealed regulator prevents any salt water from entering the first stage, which assists to keep it breathing within specs over an extended period of time.

300 bar DIN Cylinder Connection

DIN regulators are used by technical divers and are mandatory in Europe for safety reasons as the O-ring is captured on the regulator side rather than the cylinder valve. DIN regulators are more streamlined than INT/Yoke/A-clamp regulators and also lighter than the equivalent Yoke regulators, which is great for the travelling diver. Yoke regulators are generally limited to 240 bar (3500 psi). These DIN regulators can be used on up to 300 bar (4350 psi) cylinder valves, and are more suitable for demanding diving situations like technical diving, especially in environments like caves and wrecks where a bump to a Yoke valve could cause a serious gas leak. Most cylinder valves today are DIN/K valves where, using an 8 mm Allen key, an insert can be screwed in and out switching the valve from DIN (without the insert) to K/INT/Yoke (with the insert). However, this package includes a Dive Perfect DIN to Yoke 1st Stage Regulator Adaptor so that you can use the DIN regulator on INT/Yoke only cylinder vales if you plan to dive around the USA and Caribbean where K/INT/Yoke only cylinder valves might still be commonly found.

Second Stage Technology

Pneumatically Balanced 2nd Stages

In most other regulator second stage designs, the inhalation effort of the diver opens a valve inside the regulator that is held closed by spring tension.

The Dive Perfect FR-02 2nd Stage Regulators feature a pneumatically balanced valve system which means that the pressure on the second stage valve is "balanced" by allowing medium pressure air to pass through to the opposite side of the valve to help counteract the force of the spring. This reduces the inhalation effort required to open the second stage valve and substantially improves the overall ease of breathing in all diving conditions. This means that a dive on a Dive Perfect regulator is a far superior breathing experience to that of other competing regulators.

Reversible Venturi System (RVS)

The Dive Perfect Reversible Venturi System (RVS) allows the diver to control the venturi assist with greater precision due to indexable Venturi Lever. Gas flow to the diver can be directed towards the mouthpiece by indexing the venturi lever towards the plus (+) position. This allows the diver an assisted breathe resulting in a more comfortable dive with less breathing effort.

A lot of regulators have a tendency to free flow in strong current, during surf entry, or on the swim out on the surface. With the venturi lever in the minus (-) position, the air-flow in the second stage is directed onto the diaphragm, closing the valve and preventing free flow.

The Indexable Venturi Lever can therefore act as a pre-dive switch. When set in the minus (-) position the second stage will not free flow during the entry phase or if the regulator is dropped in the water. When the diver begins to use the regulator the venturi lever can be indexed toward the plus (+) position and the second stage will give the diver an assisted breathe resulting in a more comfortable dive with less breathing effort.

The Dive Perfect venturi switch is clearly marked and easy-to-use. Even a diver receiving it in an emergency can easily see how to switch it from minus to plus, regardless of what sort of hurry they might be in.

Inhalation Resistance Control Knob

The second stage regulators are equipped with an additional adjustment, which controls inhalation resistance. People who dive deep often like to be able to increase the breathing resistance.

This control knob, located beside the RVS switch, adjusts the amount of effort required to start the air flow at the beginning of the inhalation cycle. As it is turned "in" (clockwise), the opening effort will increase. This will make the second stage less sensitive to sudden changes in ambient pressure. Turning the knob "out" (anti-clockwise) will decrease the opening effort to make breathing easier.

This adjustment is particularly useful at deeper depths, or in variable conditions that affect the opening effort of the second stage, such as strong currents or while using a diver propulsion vehicle (DPV). You can use the inhalation control knob to tune your regulator to maintain its peak performance throughout the course of your dive, or you can leave it set in its mid-range position and dive with it as you would any non-adjustable second stage.

Exceeding CE EN250 Standard Performance

The Dive Perfect Matilda Streamlined Sport Diver Regulator Package meets the tough CE EN250 European standards. This means the regs have been tested on an ANSTI wet breathing simulator, which measures how much effort — "work of breathing" — it takes to move air through a regulator as it is subjected, underwater, to a precise series of depths and breathing rates.

Tests are performed at a high-pressure supply of 75 bar, at a rate of 25 breaths per minute and a tidal volume of 2.5 litres, to conform to European test standards. Per industry practice, the regs are tested in the face-forward position, and regs with breathing adjustments are set at the wide-open/no-free-flow point.

The simulator pressurises the test chamber to simulate depths of 50 metres (165 feet) of seawater. Each "breath" by the machine moves 2.5 litres of air through the regulator, and this is done at breathing rates of 15, 25 and 30 breaths a minute. These precisely measured volumes of air — 2.5 litres multiplied by the breathing rate — are called Respiratory Minute Volumes (rmv).

These regs have achieved better than 62.5 rmv @ 50 msw to meet the European conformance standard EN250. The fittest diver would be hard-pressed to keep up for more than a couple of minutes at this breathing rate and these regs will still perform well in even more-extreme conditions.

Pricing for Streamlined Sport Diver Regulator Packages

The custom regulator packages from The Scuba Doctor are fully assembled and integrated by us using brand name first and second stage regulators together with premium quality hoses, gauges, adaptors, stainless steel hardware and other accessories.

The regulator manufacturers do not endorse the installation or substitution of any non-factory part or component with their products because they do not have the ability to control or evaluate the quality and compatibility of such items. The installation of non-factory parts such as regulator hoses or other components may or may not have negative effects upon performance, function and safety. The regulator manufacturers disclaim liability for defect, damage or injury caused by the use of any non-factory parts or accessories.

Service Kits and Parts

First and second stage Regulator Service Kits, plus other genuine factory-supplied parts, are available from The Scuba Doctor.

Service by other than an authorised dealer voids the warranty on all products we sell. Improper service of dive equipment can lead to serious injury or death.

(01/15 LRB)


Connect with us on Facebook - scubadoctor  View our YouTube Channel - ScubaDoctorRye  Follow us on Instagram  View us on Pinterest - scubadoctor  Follow us on Twitter - @scubadoctor
The Scuba Doctor Australia
Boon Wurrung Country
1/49 Peninsula Ave
Rye Victoria 3941, Australia
Commonwealth Coat of Arms
We accept Purchase Orders from Government Departments & Schools
Contact
P +613 5985 1700
E diveshop@scubadoctor.com.au
-------------------------
Opening Hours
-------------------------
Shop by Category
-------------------------
Brands
Copyright © 2005-2024 by The Scuba Doctor Australia, ABN 88 116 755 170. All rights reserved. tel. +61 3 5985 1700 :: email. diveshop@scubadoctor.com.au :: Web site by it'sTechnical 2022